Low maintenance Filter Fan FF 018 Series (21m3/h to 102m3/h)
■ Very low noise
■ Minimal depth in enclosure
■ Functional design
■ Time-saving installation
■ Weather proof and UV resistant
Filter fans are used to provide an optimum climate in enclosures. The interior
temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pockets and protects the electronic components from overheating. The plastic used for the hood of this filter fan series is highly weather proof and UV light resistant.
■ Technical Data Axial fan, ball bearing
service life min. 50,000h at 25°C/77°F (65% RH)
fan body aluminium, rotor plastic
Connection 2 wires with pressure clamps 2.5mm², length 100mm
Casing (filter fan and exit filter)
Plastic according to UL94 V-0, light grey
Hood (filter fan and exit filter) Plastic according to UL94 V-0, light grey;
weather proof and UV light resistant according to UL746C (f1)
Mounting frame with double-sided industrial adhesive band for fixing to the
outside of enclosure; certain operating circumstances can
make the additional use of screws necessary (see drilling
template); included in the delivery of the filter fans is a
template for the enclosure cut-out
Filter mat G4 acc. To DIN EN 779, filtering degree 94%
Filter material
synthetic fibre with progressive construction, temperature
resistant to 100°C, self-extinguishing class F1;
moisture resistant to * RH, reusable – cleaning by
washing or vacuuming
Operating / Storage temperature -45 to +70°C (-49 to +158°F)
Prot. Type / Protection class
IP54* / I (earthed)
*Using fine filter mats type F5 increases the protection type to IP55, but reduces the air volume.
Special features
■ The self-adhesive seal of the mounting frame prevents dust and water from entering the cabinet.
■ Functional design of the intake and exit fan hoods very effectively prevents direct intrusion of falling water and dust. The advantage is that the filter mat does not get so quickly contaminated with dirt and thus does not
need to be exchanged so often.
■ The air channelling makes the filter fan particularly quiet in operation.
■ Functional and modern design enables time-saving assembly and maintenance.
■ All filter fan models are also available with integrated airflow monitor.
■ EMC versions and other voltages on request.
■ The direction of air can easily be switched by reversing the axial fan (sizes 1 to 3).
Filter Fan FF 018 SeriesArt. No. Operating
voltage Air volume,
free flow Air volume
with
exit filter Current
consumption Power
consumption Average noise level
(DIN EN ISO 4871) Depth in
enclosure Enclosure
cut-out Weight
(approx.) Approvals
01800.0-00 230VAC, 50Hz 21m³/h
16m³/h 80mA 13W 31dB (A)
45mm
97 x 97mm + 0.4 0.60kg VDE + UL File No. E234324
01801.0-00 230VAC, 50Hz
55m³/h
42m³/h 100mA 15W 40dB (A) 58mm
125 x 125mm + 0.4 1.00kg
VDE + UL File No. E234324
01802.0-00 230VAC, 50Hz 102m³/h
68m³/h 100mA 15W
39dB (A) 86mm 176 x 176mm + 0.4 1.30kg VDE + UL File No. E234324
01800.0-01 120VAC, 60Hz
24m³/h
18m³/h 160mA 13W 31dB (A) 45mm
97 x 97mm + 0.4 0.60kg UL File No. E234324
01801.0-01 120VAC, 60Hz 63m³/h
48m³/h 180mA 15W 40dB (A)
58mm 125 x 125mm + 0.4
1.00kg UL File No. E234324
01802.0-01 120VAC, 60Hz 117m³/h 78m³/h 180mA 15W 39dB (A)
86mm 176 x 176mm + 0.4
1.30kg UL File No. E234324
Time-saving assembly and maintenance
STEGO's filter fans are easily installed by one person from outside the cabinet.
1.) Make cut-out in the cabinet wall. The cut edge of the cabinet opening should be free of dirt, filings and grease.
A template for the enclosure cut-out is included in the delivery of the filter fan.
2.) Remove protective film from the sealing strips on the mounting frame. Press mounting frame into the cabinet opening. The frame stays permanently in the cabinet. (For size 176mm and up we recommend additional screw fixing.)
3.) Electrically connect the axial fan using the clip connectors. Push the unit into the mounting frame. Fix using screws.
4.) Insert the filter mat in the hood. Clip on. Finished. Changing the filter mat or fan is quickly done by one person. To change the filter mat simply remove the filter hood, insert the new mat and snap the hood back again. No tools required. Maintenance of the fan can easily be done without removing the mounting frame (2).
Exit Filter EF 118 SeriesArt. No. Depth in enclosure Enclosure cut-out
Weight (approx.)
Filter mat
Protection type
11800.0-00 16mm 97 x 97mm + 0.4 0.30kg G4 acc. To DIN EN 779, filtering degree 94% IP54*
11801.0-00 16mm 125 x 125mm + 0.4 0.40kg G4 acc. To DIN EN 779, filtering degree 94% IP54*
11802.0-00 16mm 176 x 176mm + 0.4
0.60kg
G4 acc. To DIN EN 779, filtering degree 94%
IP54*
Filter Mats FM 086 / FFM 086Filter mat
89 x 89mm 118 x 118mm
168 x 168mm
G4 (1 packing unit = 3 pcs.)
Art. No. 08600.0-00 Art. No. 08601.0-00 Art. No. 08602.0-00
F5 (1 packing unit = 3 pcs.) Art. No. 08603.0-00 Art. No. 08604.0-00
Art. No. 08605.0-00
Filter Fan with Airflow Monitor FFLC 218Art. No. Operating
voltage Air volume,
free flow Air volume
with exit filter Current
consumption Power
consumption Average noise level
(DIN EN ISO 4871) Depth in
enclosure Enclosure
cut-out Weight
(approx.)
21800.0-00 230VAC, 50Hz
21m³/h 16m³/h 80mA 13W
31dB (A)
45mm
97 x 97mm + 0.4 0.60kg
21801.0-00
230VAC, 50Hz
55m³/h
42m³/h
100mA
15W
40dB (A)
58mm
125 x 125mm + 0.4 1.00kg
21802.0-00
230VAC, 50Hz
102m³/h 68m³/h
100mA
15W
39dB (A)
86mm
176 x 176mm + 0.4
1.30kg
21800.0-01
120VAC, 60Hz
24m³/h
18m³/h 160mA
13W
31dB (A)
45mm
97 x 97mm + 0.4
0.60kg
21801.0-01
120VAC, 60Hz
63m³/h
48m³/h
180mA
15W
40dB (A)
58mm
125 x 125mm + 0.4
1.00kg
21802.0-01 120VAC, 60Hz
117m³/h
78m³/h
180mA
15W
39dB (A)
86mm
176 x 176mm + 0.4 1.30kg
For technical data see Airflow Monitor LC 013/LCF 013 (Normally Closed, Normally Open)
上海伏威机电设备有限公司主营:编码器,传感器,电动机马达,液压气动,工控机械传动;欢迎与我们联系!
电脑版:STEGO通风过滤FF018 Series21m3/h to 102m3/h